Newsletter!

How to Control Electric Water Heater Using Switches?

How to Control Electric Water Heater Using Switches? . Electric water heaters are indispensable appliances in modern households. They provide hot water for various uses, including bathing, cooking, and cleaning. However, the efficient management of these systems is crucial for energy conservation and cost reduction. Switches play a vital role in controlling water heaters, allowing users to turn them on and off or schedule their operation to align with specific needs.

How to Control Electric Water Heater Using Switches
How to Control Electric Water Heater Using Switches

Read More : What Are the Types of Switches – Construction and Working

Types of Switches Used for Electric Water Heaters

  1. Manual Switches:
    These are traditional on/off switches that provide direct control over the heater’s operation. They’re simple, affordable, and reliable.
  2. Timer Switches:
    Timer switches automate the operation of the water heater, enabling it to run during predefined times. This helps reduce energy consumption and ensures hot water availability when needed.
  3. Smart Switches:
    Smart switches integrate with smart home systems, allowing remote control via mobile apps or voice commands. They often come with advanced features like energy usage tracking and AI-based automation.

How Electric Water Heater Switches Work

Switches control the flow of electricity to the heating element in the water heater. When turned on, the switch completes the circuit, allowing electricity to heat the water. When turned off, the circuit is broken, stopping the heating process. Advanced switches like timers and smart models incorporate additional features for automation and efficiency.

Controlling of Water Heater using Single Pole, Two Poles & Intermediate Switches?

In our electric water heater wiring series, we will be showing that how to control the water heater using single way, two way, three way and four-way (intermediate) switches.

Read More : How to Wire Switches in Series?

Step-by-Step Guide:

  1. Locate the power source and turn it off.
  2. Identify the wires connected to the water heater.
  3. Connect the switch according to the manufacturer’s instructions.
  4. Test the installation by turning the power back on and operating the switch.

Controlling of Water Heater using Single-Pole Switch

To control a non-continuous (non-simultaneous) water heater using a single way or one-way switch, we must use a 10 gauge wire size with a minimum 30 amp circuit breaker. In our case, we have connected the water heater directly to a 30 amperes single way switch which is protected by a 30 amp circuit breaker from the main distribution board. The down position of the switch is used to break the line supply to the water heater. In the case of 240V heater, a single line cut off is sufficient to switch off the water heater. Also, don’t forget to do the proper grounding to the switch and water heater.

How-to-Control-Electric-Water-Heater-with-Single-Way-Switch-One-way-switch
How-to-Control-Electric-Water-Heater-with-Single-Way-Switch-One-way-switch

Read More : How to Wire Switches in Parallel: A Step-by-Step Guide

Good to know:

  • Always use 10 gauge wire for 240V, 30 amp circuit breaker according to the rating. 12 gauge can be used for single phase 120V according to the appliance rating.
  • Use a minimum of 30A switch for 240V with 30A protection CB.
  • A 240V breaker or switch can be used for 120V while, 120V rated breakers and switches can’t be used for 208, 240, 277 or 480V.
  • Switch must be installed only and only on line (hot or phase) wire instead of neutral wire.

Controlling of Water Heater using Double Pole Switch

A double pole switch can be also used to control the ON/OFF operation of electric water heaters. In our case of 240V water heater, we have used a 30 amp double pole switch protected by a 30 amp circuit breaker form the main supply panel.

This way, both lines (hot or phase) wires are turned off by switch. Only breaking a single line supply will work perfectly, but we are still able to use the double pole switch instead of single pole switch as it makes sure to turn the power off to the water heater. This way, the double pole acts as a safety switch as well.

Safety switches are required in tankless water heaters, HVAC (heating, ventilation, and air conditioning), commercial water heaters or when the main circuit breaker box is not within sight.

Read More : What Is the Difference Between Sensor and Actuator?

Good to know:

  • Always use the proper wiring diagram according to the user manual provided by the manufacturers.
  • A 240V AC water heater element can be connected to the 120V AC.
  • A 120V AC water heater element can’t be used for 240 or 230V.

Controlling of Water Heater using DPST Switch

The following wiring diagram shows a DPST (Double Pole, Single Throw) switch rated for 120V to 277V and fed-up by 240V 2-pole breaker is used to wire and control a water heater. It clearly shows the common (dark screws) are connected to the 240V supply voltage via Hot 1 and Hot 2. The L1 and L2 (brass screws are directly connected to the water heater. Since it is a 240V circuit, hence no Neutral is needed.

How-to-Control-Water-Heater-using-double-pole-Switch
How-to-Control-Water-Heater-using-double-pole-Switch

Read More : How to Wire Analog and IP PTZ Cameras with DVR and NVR?

Finally, the ground wire is connected to both the DPST switch green screw and the terminal box of the water heater. This way, the ON and OFF operation will close or open both the sources i.e. Line 1 and Line 2.

Similarly, the following wiring diagram shows controlling of 240V non-continuous water heater thermostat and element using 20A double pole, single throw switch.

230V-240V-AC-Non-Continuous-Dual-Element-3.5kW-Water-Heater-Thermostat-Wiring
230V-240V-AC-Non-Continuous-Dual-Element-3.5kW-Water-Heater-Thermostat-Wiring

Controlling of Water Heater from Two Places using Two, 3-Way Switches

Using the following diagram, we can control an electric water heater from two different places, similar to the staircase wiring diagram where a single light bulb can be controlled from two places using three way switches.

In case of single phase 120V supply, the neutral is directly connected to the water heater where the hot wire (live or line) is connected to the common of a three way switch. Both 3-way switches are connected via traveler wires (blue) while the common of the second 3-way switch is connected to the water heater. A proper grounding and 30 A circuit breaker with 10 gauge wire should be used for 240V. In case of 120V, a 12 gauge wire should be used according to the rating. Only one live wire is enough to cut off the power supply through a 3-way switch. Overall, it is known as a 3-way circuit. Both switches and circuit breaker rating is 30 amperes.

How-to-Control-Water-Heater-from-Two-Places-using-Two-3-Way-Switches
How-to-Control-Water-Heater-from-Two-Places-using-Two-3-Way-Switches

Read More : What is a Tactile Sensor?

Good to know:

A switch rated for:

  • 120V can only be used for 120V.
  • 240V can be used for 120V, 240V but not for 277V (Commercial applications)
  • 120-277 can be used for 120V, 240V and 277V.

Controlling of Water Heater from Three Places using Two, 3-Way & Four Way Switch

If we connect an intermediate (4-way) switch in between two 3-way switches in the above circuit, we will be able to ON/OFF the water heater from three different places as shown in below wiring diagram for 240V, 230V and 120V AC.

The rating of circuit breaker and all switches including three way and 4 way is 30 amp. You may use proper rated switches and breaker size for single phase 120V. Don’t forget to do proper earthing/grounding to the water heater and switches.

Control-Water-Heater-from-3-Places-using-2-3-Way-Switches-and-4-Way-Switch-Intermediate-Switch
Control-Water-Heater-from-3-Places-using-2-3-Way-Switches-and-4-Way-Switch-Intermediate-Switch

Good to Know:

  • A switch rated for 15A, 120V can be used on a 20A, 120V circuit.
  • A switch rated for 20A, 120V can’t be used on household 15A, 120V circuits.
  • A switch rated for 120V can’t be used on 240V circuits and vice versa.
  • A 240V switch can be used on a 120V circuit if the ampere rating is the same.
  • A 120V switch can’t be used on 240V circuit even if current rating in amperes are the same.

Read More : What is Motor Starter?

Warning and Precautions

  • Disconnect the power before replacing, repairing, troubleshooting, maintenance and installation electrical appliances and equipment.
  • Use the suitable voltage and ampere rating of switch with appropriate wire size and proper size of breaker according to the load rating.
  • Failure to do so can result in electrical shock, serious injury, fire or even death.
  • Perform a continuity test for the switch terminal before wiring and installation. Use 10 gauge wire for 240V and 12 Gauge for 120V in the above wiring tutorials. Follow the user manual guide or contact a licensed electrician for proper installation. All the above wiring diagrams are for non-simultaneous (non-contentious) heating elements and thermostat operation.
  • Red color illustrates the Line or Phase wire and Black color shows the Neutral Wire in the above figures. You may follow your regional wiring color codes i.e. IEC or NEC.
  • Please follow the manual instruction, local area codes or contact a licensed electrician for proper installation.
  • The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in the wrong format. So please! Be careful because it’s all about electricity and electricity is too dangerous.

Advantages of Using Switches for Electric Water Heaters

  • Energy Efficiency: Precise control reduces unnecessary energy consumption.
  • Cost Savings: Lower energy usage translates to lower utility bills.
  • Improved Safety: Switches help prevent overheating and reduce the risk of electrical hazards.

Troubleshooting Common Issues with Water Heater Switches

  1. Switch Malfunction:
    Check for loose connections and replace faulty components if necessary.
  2. Connectivity Problems (for smart switches):
    Ensure a stable internet connection and update the app or firmware.
  3. Electrical Safety Tips:
    Regularly inspect wiring for wear and tear and consult a professional for repairs.

Read More : What is PNP Transistor?

FAQs: All About Electric Water Heater Switches

1. Can I install a timer switch myself?
Yes, but ensure you follow the safety guidelines and instructions provided by the manufacturer.

2. Are smart switches compatible with all water heaters?
Most smart switches are compatible with standard electric water heaters, but always check compatibility before purchasing.

3. How do timer switches save energy?
They prevent the water heater from running continuously by scheduling specific operating times.

4. Is it safe to use switches with wet hands?
No, always dry your hands before operating any electrical switch to avoid shocks.

Related Topics
How to Control Electric Water Heater Using Switches?
Engineering Reference
Subscribe to our

Newsletter

We will update you with all the latest books and references.