Contactors and relays are essential components in electrical systems, serving as switches for controlling power flow. Both devices share similarities in their basic function, so there is usually confusion about the difference between a contactor vs relay! Typically used for switching the loads, contactors and control relays are integrated into an electrical circuit subject to the resultant load. A wrong decision in deciding the electrically operated switches for a particular application can cost a huge amount of investment, damaging the integrated electrical circuit. By understanding the fundamental principles and technical aspects of contactor vs relay, you will be better equipped to make informed decisions when designing or maintaining electrical systems.

Basic Definitions

What is a Contactor?


A contactor is an electromechanical switch designed to control the flow of electrical current in high-power applications. It consists of three main components: a coil, contacts, and an enclosure. When energized, the coil generates a magnetic field, which attracts the contacts, causing them to close and complete the circuit. This allows the flow of current through the connected electrical load.

Contactors are typically used in applications where high currents, typically above 15 amperes, need to be switched on and off. These are known for their capability to handle currents of over 5000 amperes and high power over 100 kW. [1]  Contactors are designed to handle high inrush currents when starting large motors or other inductive loads. The contacts in a contactor are usually made of materials with high electrical conductivity, such as silver or copper, to minimize contact resistance and ensure efficient current flow. The enclosure, often made of plastic or metal, protects against environmental factors and electrical hazards.

One of the key features of contactors is their ability to handle high currents while maintaining a relatively small form factor. This is achieved through arc suppression techniques, such as arc chutes or blowout magnets, which help extinguish the electrical arc that forms when the contacts open or close. These features enable contactors to operate reliably and safely in demanding electrical environments.

What is a Relay?


A relay is an electromechanical or solid-state device that serves as a switch to control the flow of electrical current in low to medium-power applications. It consists of a coil, contacts, and an enclosure similar to a contactor. When the coil is energized, it generates a magnetic field that attracts the contacts, either closing or opening the circuit, depending on the relay’s configuration. This allows the flow of current through the connected electrical load.

Relays are commonly used in applications with lower current requirements, typically below 15 amperes. They are often employed to control smaller loads or as an intermediary between a low-power control signal and a higher-power load. The contacts in a relay can be made of various materials, such as silver or gold, depending on the specific application requirements. The enclosure, typically plastic, protects against environmental factors and electrical hazards.

One of the main advantages of relays is their ability to isolate the control circuit from the load circuit. This means that a low-power control signal can switch a higher power load without the risk of electrical interference or damage to the control circuit. Additionally, relays can be designed with multiple contacts, allowing them to control multiple circuits simultaneously. These also provide different switching configurations, such as single-pole double-throw (SPDT) or double-pole double-throw (DPDT) arrangements. [2]

Key Differences Between Contactors and Relays

Load Capacity

Load capacity is the maximum allowable force that can be applied to a stage in a specified direction while meeting stage specifications. [3] One of the primary differences between contactors and relays is their load capacity. Contactors are designed to handle high-current loads, while relays are suitable for low to medium-current loads. This difference in load capacity results from the design and construction of the devices, with contactors featuring larger and more robust auxiliary contacts to accommodate higher currents. Special contactors are utilized to switch three phases of power simultaneously.

In practical terms, contactors are often used in applications involving large motors, heavy machinery, or other high-power equipment, where the current requirements can reach hundreds or even thousands of amperes. On the other hand, relays are more commonly found in control systems, automation, and low-power devices, where the current requirements are relatively modest. Relays are typically limited to single-phase applications.

The choice between a contactor and a relay for a specific application depends on the current requirements of the load. When starting motors or inductive loads, considering both the continuous current rating and the initial surge of current, known as inrush current, is essential. Selecting a device with an appropriate load capacity ensures reliable operation and minimizes the risk of device failure.

Switching Mechanism


Switching is a way to control continuity between two points in an electrical circuit. [4] Another key difference between contactors and relays is the way they switch electrical currents. Both devices use an electromechanical mechanism, where an energized coil generates a magnetic field that attracts the spring-loaded contacts, either opening or closing the circuit. However, the specific design and construction of the switching mechanism can vary between the two devices, leading to differences in performance and suitability for specific applications.

In contactors, the switching mechanism is designed to handle high currents and minimize the effects of electrical arcing. This is achieved through the use of arc suppression techniques, such as arc chutes or blowout magnets, which help extinguish the electrical arc that forms when the contacts open or close.  Contactors typically have larger contacts made of materials with high electrical conductivity, like silver or copper. This ensures efficient current flow by minimizing contact resistance.

Conversely, relays have a more compact switching mechanism, suitable for lower current applications. The contacts in relays can be made of various materials, such as silver or gold, depending on the specific application requirements. Relays are less robust than contactors in preventing wear and damage caused by electrical arcing in high-current situations.  Capacitor banks can be used to reduce the inrush current when a relay switches on a high-power load.

The choice between a contactor and a relay for a specific application depends on the switching requirements, including the current levels, the frequency of switching, and the need for arc suppression.  Selecting the most appropriate device for your application minimizes the risk of device failure or damage to the connected equipment.

2.3. Open/closed contact standards

Relays are designed to operate both normally open and normally closed depending on the required function, but contactors are designed to operate with normally open contacts. This means there is no contactor connection when the coil is de-energized, which is not necessarily true regarding relays.

An electronic relay – upside down

Easy to remember:

Normally closed (NC) = Current flows

Normally open (NO) = Current does not flow

In normally open conditions, no current flow is in its normal or initial state. But energizing it and switching it on will close the contacts to allow it to flow current. On the other hand, normally closed in NC contacts is a condition with a flow of current in its normal or initial state. But contrary to what happens in NO, de-energizing and switching it on will open the contact to stop the current flow. Contactors are typically used to switch high-voltage circuits, while relays are typically used to switch low-voltage circuits.

2.4. Size and Construction

The size and construction of contactors and relays also differ, with each device designed to accommodate its intended applications and load capacities.

Contactors are generally larger and more robust than relays due to their ability to handle high currents. The contacts in contactors are typically made of materials with high electrical conductivity to minimize contact resistance and ensure efficient current flow. Contactors are typically designed to handle AC and DC loads; their coil draws significant power. Additionally, they come with provisions for arc suppression to prevent any damage from electrical arcing.

Conversely, relays are more compact and lightweight, making them suitable for low to medium-current applications. The contacts in relays can be made of various materials depending on the specific application requirements. They are designed to open or close circuits electronically or electromechanically. Since they manage smaller loads, relays don’t usually require the same level of arc suppression as contractors.

When selecting between a contactor and a relay for a specific application, it is essential to consider the size and construction requirements of the device. This includes factors such as available space, mounting options, and environmental conditions. By understanding the differences in size and construction between contactors and relays, you can choose the most appropriate device for your application, ensuring reliable operation and minimizing the risk of device failure or damage to the connected equipment.

2.5. Electrical Noise

Electrical noise, or electromagnetic interference (EMI), is an unwanted electrical signal disturbance affecting electronic devices’ performance and reliability. Contactors and relays, as electromechanical switches, can generate electrical noise during their operation, with the level of noise depending on the design and construction of the device.

Due to their larger size and higher current handling capabilities, contactors can generate more electrical noise than relays. The opening and closing of contacts in a contactor can create electrical arcs, which produce electromagnetic radiation that can interfere with nearby electronic devices. To mitigate this issue, contactors often employ arc suppression techniques to extinguish the electrical arc and reduce the amount of electrical noise generated.

Conversely, relays generate less electrical noise due to their smaller size and lower current handling capabilities. However, they can still produce some electrical noise during their operation, particularly when switching inductive loads. Solid-state relays use semiconductor components that offer lower levels of electrical noise, making them suitable for applications where EMI is a concern.

When choosing between a contactor and a relay for a specific application, it is essential to consider the potential impact of electrical noise on the performance and reliability of the connected equipment. In situations where EMI is a concern, such as in sensitive electronic systems or environments with strict electromagnetic compatibility (EMC) requirements, selecting a device with lower electrical noise generation may be more appropriate.

2.6. Lifespan and Durability

The lifespan and durability of contactors and relays are important factors when selecting the appropriate device for a specific application. Both devices are subject to wear and tear due to their electromechanical nature. Still, the extent of wear and the expected lifespan can vary depending on the design, construction, and operating conditions.

Contactors, designed to handle high currents, typically have a longer lifespan and greater durability than relays. The contacts in contactors are made of materials with high electrical conductivity, which minimize contact resistance and ensure efficient current flow. Additionally, contactors often employ arc suppression techniques which help extinguish the electrical arc that forms when the contacts open or close, reducing wear on the contacts and extending the device’s lifespan.

Relays have a shorter lifespan and lower durability than contactors due to their smaller size and lower current handling capabilities. The contacts in relays wear out more quickly than those used in contactors, particularly when switching inductive loads or operating at high frequencies. Solid-state relays offer improved durability and longer lifespans compared to electromechanical relays. Still, they may not be suitable for all applications due to their specific characteristics and limitations.

Factors that can affect the lifespan and durability of contactors and relays include the frequency of switching, the current and voltage ratings, and the type of load being switched. This also includes the environmental conditions, such as temperature, humidity, and the presence of dust or corrosive substances. By understanding the differences in lifespan and durability between contactors and relays, you can select the right device to ensure reliable operation and minimize the risk of device failure.

Recommended reading: General Purpose Port Protection Against Electrical Stress

Parameters Contactor Relay
Definition An electromagnetic switch that can carry a current load of up to 12,000 amperes An electromagnetic switch that can carry a current load of up to 10 amperes
Size Large in size Comparatively smaller or of the same size as the contactor
Cost More cost Less cost
Auxiliary Contacts It consists of at least one set of three-phase power contacts, and built-in auxiliary contacts can also be present Comes with at least two contacts-NC and NO
Load 9A and above 10A or below
Voltage Maximum 1000 volts Maximum 250 volts
Phase 1 or 3 phase 1 phase
Life Span Shorter
Longer
Switching Device Speed The average switching speed for a contactor is between 20 and 250 The average switching speed for a relay is between 3 and 100 ms
Coil Power Troubleshooting More coil power consumption Less coil power consumption
Troubleshooting They do not come with any troubleshooting features Relays have better troubleshooting features, such as flags or small lights indicating the position of the relay
Humming Noise Sound level of humming noise is higher The sound level is lesser than that of a contactor
Maintenance  Requires more maintenance Requires less maintenance
Applications At least three-phase electrical networks, such as transformer or induction motor Single-phase applications

Applications of Contactors and Relays

Contactors and relays for electric equipment motor starter control and industrial machines

Industrial Applications

Contactors and relays are crucial in controlling and managing electrical loads in industrial settings. Their specific applications depend on load capacity, switching requirements, and environmental conditions.

Contactors are commonly used in industrial applications involving high-power equipment, such as large motors, heavy machinery, heating, ventilation, and air conditioning (HVAC) systems. These devices require high current handling capabilities, which contactors are designed to accommodate. For instance, contactors can be found in motor control centers responsible for starting and stopping large motors and providing overload protection. [5] Additionally, contactors can be used in power distribution systems to control the flow of electricity to various parts of an industrial facility. In automotive applications, contactors are typically used for high-power loads, including starter motors, EV motors, air conditioning compressors, and electric power steering motors.


Relays, on the other hand, are more suitable for low to medium-current applications in industrial environments. They are often employed in control systems, automation, and safety circuits, where their ability to isolate the control circuit from the load circuit is essential. For example, relays can be used in programmable logic controllers (PLCs) to control the operation of machinery or in safety systems, such as emergency stop circuits, to ensure the safe operation of equipment. Relays can also be found in monitoring and alarm systems, which activate alarms or initiate corrective actions in response to specific conditions, such as temperature or pressure deviations.


By understanding the specific requirements of industrial applications and the capabilities of contactors and relays, you can select the most appropriate device, ensuring reliable operation and optimal performance of your electrical systems.

Commercial Applications

In commercial environments, contactors and relays control and manage electrical loads in various applications.

Contactors are often employed in commercial applications that involve high-power equipment, such as HVAC systems, lighting control, and large appliances. For example, contactors can be used in commercial buildings to manage the operation of air conditioning units, ensuring efficient energy usage and maintaining a comfortable indoor environment. In lighting control systems, contactors can be utilized to switch large groups of lights on and off, either manually or based on a predetermined schedule, helping to reduce energy consumption and extend the lifespan of the lighting equipment.


Relays, on the other hand, are more suitable for low to medium-current applications in commercial settings. They are commonly found in control systems, automation, and safety circuits, where their ability to isolate the control circuit from the load circuit is essential. For instance, relays can be used in building automation systems to control various aspects of the building’s operation, such as lighting, heating, and security. In safety systems, relays can be employed to monitor and control emergency lighting, fire alarms, and access control systems, ensuring the safety and security of the building’s occupants.


By understanding the specific requirements of commercial applications and the capabilities of contactors and relays, you can select the most appropriate device, ensuring reliable operation and optimal performance of your electrical systems.

Residential Applications

In residential environments, contactors and relays have various applications in controlling and managing electrical loads.

Contactors are used in residential applications that involve high-power equipment, such as central air conditioning systems, electric water heaters, and solar power installations. For example, contactors can be employed in solar power installations; contactors can be utilized to switch between grid power and solar power, depending on the availability of solar energy and the requirements of the electrical loads in the home. [6]

Relays are more suitable for low to medium-current applications in residential settings. Relays can be used in home automation systems to control various aspects of the home’s operation, such as lighting, heating, and security. In safety systems, relays can be employed to monitor and control smoke detectors, carbon monoxide alarms, and security systems, ensuring the safety and security of the home’s occupants.

By understanding the specific requirements of residential applications and the capabilities of contactors and relays, you can select the most appropriate device, ensuring reliable operation and optimal performance of your electrical systems.

Selecting the Right Device for Your Application

Load Requirements

When choosing between a contactor and a relay for a specific application, the load requirements is one of the most critical factors to consider. This includes both the continuous current rating and the inrush current, which is the initial surge of current that occurs when starting a motor or other inductive loads.

To determine the load requirements, you should first identify the current and voltage levels of the electrical load you need to control. This information can typically be found on the equipment’s nameplate or in the manufacturer’s documentation. It is essential to select a device with a continuous current rating that meets or exceeds the maximum current requirement of the load. Additionally, consider the inrush current, which can be significantly higher than the continuous current rating, especially for inductive loads like motors.

Once you have determined the load requirements, you can compare the specifications of contactors and relays to find a suitable device. Contactors are generally more appropriate for high-current applications, while relays are better suited for low to medium-current applications. By selecting a device with the appropriate load capacity, you can ensure reliable operation and minimize the risk of device failure or damage to the connected equipment.

Environmental Factors

Environmental factors can also play a significant role in determining the most suitable device, whether a contactor or a relay, for your specific application. These factors include temperature, humidity, dust, and the presence of corrosive substances, which can affect the performance, reliability, and lifespan of the device.

Contactors, with their robust construction and larger size, are generally better suited for harsh environments. where high temperatures, humidity, or dust may be present. The enclosures of contactors, typically made of plastic or metal, protect against environmental factors and electrical hazards. Additionally, contactors often feature arc suppression techniques, such as arc chutes or blowout magnets, which help extinguish the electrical arc that forms when the contacts open or close, reducing wear on the contacts and extending the device’s lifespan.

Relays are more compact and may be less resistant to harsh environmental conditions. The enclosures of relays, typically made of plastic, protect against environmental factors and electrical hazards but may not be as durable as the enclosures used in contactors. Solid-state relays, which use semiconductor components instead of mechanical contacts, can offer improved resistance to environmental factors. Still, they may not be suitable for all applications due to their specific characteristics and limitations.

When selecting between a contactor and a relay for a specific application, it is essential to consider the environmental conditions in which the device will operate. By understanding the differences in the construction and materials used in contactors and relays, you can choose the most appropriate device to ensure reliable operation.

Cost Considerations

Cost considerations can be significant in the decision-making process when selecting between a contactor and a relay for a specific application. The costs associated with these devices can vary depending on factors such as load capacity, construction materials, and additional features, such as arc suppression techniques.

Contactors, due to their larger size and higher current handling capabilities, are generally more expensive than relays. The materials used in contactors, such as silver or copper contacts, can contribute to their higher cost. Additionally, the arc suppression techniques employed in contactors, such as arc chutes or blowout magnets, can add to the overall cost of the device.

Relays, on the other hand, are typically less expensive than contactors, making them a more cost-effective option for low to medium-current applications. However, the cost of relays can vary depending on the specific materials used for the contacts, such as silver or gold, and the type of relay, such as electromechanical or solid-state. Solid-state relays, which use semiconductor components instead of mechanical contacts, can be more expensive than electromechanical relays but offer improved durability and lower electrical noise generation.

When considering the cost of contactors and relays; it is essential to factor in the initial purchase price and the long-term costs associated with the device, such as maintenance, replacement, and energy consumption. By understanding the cost implications of contactors and relays and considering the specific requirements of your application, you can make an informed decision that balances performance, reliability, and cost-effectiveness.

Installation and Maintenance

Installing Contactors and Relays


Proper installation of contactors and relays is essential to ensure reliable operation and minimize the risk of device failure or damage to the connected equipment. While the specific installation procedures may vary depending on the manufacturer’s recommendations and the type of device, some general guidelines can be followed for both contactors and relays.

  1. Choose the appropriate location: Select a suitable location for the device, considering available space, mounting options, and environmental conditions. Ensure that the device is installed in a clean, dry, and well-ventilated area, away from heat, moisture, or excessive vibration sources.

  2. Mount the device securely: Use the appropriate mounting hardware, such as screws or DIN rail clips, to securely attach the device to a panel, enclosure, or other suitable surface. Ensure that the device is mounted in the correct orientation, as the manufacturer specifies.

  3. Wire the device according to the manufacturer’s instructions: Follow the wiring diagram and guidelines to connect the device to the control circuit and the load. Use the appropriate wire size and type, as specified by the manufacturer, and ensure that all connections are secure and properly insulated.

  4. Verify proper operation: Before energizing the device, double-check all connections and ensure that the device is installed and wired correctly. Once the device is energized, test its operation by manually activating the control circuit and observing the response of the load. Verify that the device operates as expected and that there are no signs of overheating, arcing, or other issues.

By following these general guidelines and the specific instructions provided by the manufacturer, you can ensure a successful installation of contactors and relays, providing reliable operation and minimizing the risk of device failure or damage to the connected equipment.

Troubleshooting and Maintenance


Regular maintenance and timely troubleshooting of contactors and relays work is essential to ensure their reliable operation and extend lifespan. While the specific maintenance procedures and troubleshooting steps may vary depending on the manufacturer’s recommendations and the type of device, some general guidelines can be followed for both contactors and relays.

  1. Inspect the device regularly: Perform visual inspections to check for wear, damage, or contamination signs. Look for signs of overheating, such as discoloration or deformation of the enclosure or contacts. Check for loose or corroded connections, leading to increased resistance and reduced performance.

  2. Clean the device as needed: Remove dust, dirt, and other contaminants using a soft brush or compressed air. Be cautious not to damage the main contacts or other sensitive components during cleaning. If necessary, use a mild cleaning solution and a soft cloth to remove stubborn dirt or grease, but ensure the device is completely dry before re-energizing it.

  3. Check the contacts for wear: Examine the set of contacts for signs of wear, such as pitting, erosion, or excessive buildup of contact material. If the power contacts are severely worn or damaged, these may need to be replaced to maintain reliable operation. Consult the manufacturer’s guidelines for specific information on contact replacement and maintenance intervals.

  4. Test the device’s operation: Periodically test the operation of the contactor or relay by manually activating the control circuit and observing the response of the load. Verify that the device operates as expected and that there are no signs of abnormal behavior, such as chattering, arcing, or excessive noise.

  5. Monitor the device’s performance: Keep track of the device’s performance over time, noting any changes in operation, such as increased response times, reduced contact force, or increased electrical noise. These changes may indicate that the device requires maintenance or replacement.

By following these general guidelines and the specific instructions provided by the manufacturer, you can ensure the proper maintenance and troubleshooting of contactors and relays, providing reliable operation and minimizing the risk of device failure or damage to the connected equipment.

Conclusion

In summary, contactors and relays are essential components in electrical systems, serving as switches for controlling power flow. While they share similarities in their basic function, they differ in load capacity, switching mechanisms, size, construction, electrical noise generation, and lifespan. Understanding these differences and considering factors such as load requirements, environmental conditions, and cost can help you select the most appropriate device for your specific application, ensuring reliable operation and optimal performance of your electrical systems.

FAQ

What is the main difference between a contactor and a relay?

Relays are generally used for lower-power applications and can switch multiple contacts simultaneously. They are suitable for controlling small electrical loads. Conversely, contactors are designed to control high-power circuits and are typically used in industrial applications

What is contactor and its application?

A contactor is a special type of relay used for switching an electrical circuit on or off. They are most commonly used with electric motors and lighting applications

What is the difference between relay solenoid and contactor?

As already discussed, relays are at the low end when it comes to carrying capacity, followed by solenoids and contactors. While relays require little space and can be purchased economically, they cannot handle enough current. On the other hand, contractors can handle enough current to help power heavy equipment

How do contactors and relays work together?

A contactor is an electrical device that is widely used for switching circuits on and off. As such, electrical contactors form a subcategory of electromagnetic switches known as relays. A relay is an electrically operated switching device that uses an electromagnetic coil to open and close a set of contacts

What are the applications of relay and contactor?

Contactors are commonly used in high-power applications, such as large motors, heavy machinery, and HVAC systems. Relays are often employed in control systems, automation, and low-power circuits, where their ability to isolate the control circuit from the load circuit is essential

Can I replace contactor with relay?

Functionally, relays and contactors fulfill the same role in a circuit which is to provide isolation between a control circuit and an output circuit. Inherent advantages such as small size, PCB mount capability, and low cost allow engineers to replace contactors with relays in several applications

Does relay need AC or DC?

Relays can work with both AC and DC, depending on their design. The relay contacts often have AC and DC ratings for current and voltage. This means they can switch either type of current. However, the relay coil determines the specific type needed

Do relays have polarity?

This means that generally the operating coils do not have polarity. There are some non-polarized relays, such as those with built-in operation indicators or surge-absorbing diodes, whose operating coils have polarity. Polarized relays use the magnetic flux of the permanent magnet in their electromagnetic sections

Share this post:

Related Tips

Reading Time: 10:5 min

What is the Suitable Wire Size for 20A Breaker and Outlet?

How to Find the the Right Wire Size for a 20-Amp Breaker and Outlet Based on NEC? Choosing the the…

View post

Reading Time: 7:39 min

Why Do We Need to Install a Starter with a Motor?

Why Do We Need to Connect a Starter with Electrical Motors? Essential and Need of Starter with Motor A starter is a device used…

View post

Reading Time: 4:22 min

Why are Generators and Alternators Rated in kVA, Not in kW?

Why is an Alternator or Generator Rated in kVA, Not in kW? As we already know that why is a transformer…

View post

Reading Time: 4:41 min

Why Does AC Need More Insulation than DC at the Same Voltage Level?

Why Does AC Voltage Require More Insulation than DC Voltage for the Same Working Voltage Level? For the same working…

View post

Reading Time: 3:54 min

Why is a Power Plant Capacity Rated in MW and not in MVA?

Why is the Rating of a Power Plant Capacity Expressed in MW instead of MVA? For the following reasons, a…

View post

Reading Time: 6:36 min

Why are Overhead Power Lines Loose on Electric Poles & Towers?

Why are Overhead Power Lines Loose on Utility Poles and Transmission Towers? Transportation of people, goods, and services today is…

View post

Reading Time: 9:31 min

Why Radio Waves Are Chosen For Close Range Transmission?

Why Radio Waves Are Chosen For Close Range Transmission? INTRODUCTION Back then in the stone ages, information were disseminated either…

View post

Reading Time: 6:5 min

Why Don’t Birds and Squirrels Get Electrocuted on Power Lines?

Why Don’t Birds Setting on Power Lines Get Electrocuted? We mentioned many times that electricity is our best friend as…

View post
Subscribe to our

Newsletter

We will update you with all the latest books and references.