Login/SignupNewsletter!

AC or DC – Which One is More Dangerous And Why ?

Table of content

  • 8:35 min

  • 0 comments
  • 21 Aug 2024
  • Ahmed Badry

AC or DC – Which One is More Dangerous And Why ?

First of all, keep in mind that both AC and DC voltage and Current are dangerous and hazardous. Both are our friends and worst enemies as well as they won’t miss you if you give it a chance.

AC is more serial killer as AC with less frequency (50 Hz in EU and 60 Hz in US) is more dangerous than the DC having the same level of voltage. In other words, 230V AC (or 120V AC) is more dangerous than 230V DC or 120V DC respectively. But keep in mind that DC has the ability to roast you i.e. if we say AC is more dangerous, it doesn’t mean that DC will only play with you. Stay away and don’t trust both.

AC voltage and current with low frequency i.e. 50 Hz or 60 Hz is more dangerous than AC with higher frequency (say 500 0r 600 Hz). Same is the case i.e. AC Currents and voltages are three to five times more dangerous than DC having the same level of voltage.

In case of DC voltage and currents, It causes a single convulsive contraction (a jerky and uncontrollable process in which muscles become shorter and tighter) which pushes the victim away from the DC current or voltage source they touched.

In case of AC voltage and currents, it causes tetany (a condition marked by intermittent muscular spasms) or extended muscle contraction which leads to freezing the victim (or part(s) of the body) touching the AC voltage or current source.

Due to the alternating nature behavior of AC, it causes the heart’s pacemaker neurons into atrial fibrillation which is more dangerous than DC, where cardiac standstill (due to ventricular fibrillation) occurs in case of electric shock. In this case, there is a better chance for “frozen heart” to get back on the normal track as compared to fibrillating heart caused by AC. In those cases, defibrillating equipment (which supplies DC units to halt the fibrillation and bring back the heart to the normal condition) are used as emergency medical service.

Generally, the final decision depends on multiple factors like, human body resistance, wet or dry skin or place,  thickness of the skin, weight, sex, age, level of current and voltages, frequency etc.

If we consider the minimum level of AC and DC voltages, 50V AC in Dry condition and 25V in humid and wet places and up to 120V DC are considered safe in case of direct or indirect contacts with electrical installations. The above statement and the following table shows that AC Current and Voltage are more dangerous than DC.

For example, In case of AC, the safest limit is 50V (or 25V in humidity) where in DC, the safe limit is 120V DC. Same is the case for current, i.e. lower currents are needed for the same effect on the human body compared to DC which is low. The following table shows the story of AC and DC and its effects on the human body.

Always Remember: Current Kills, Not the Voltage. But Voltage is necessary to drive the Current. I.e. Amperes are responsible for electrocution, Not the Volts.

AC in mA (50Hz) DC in mA Effects
0.5 – 1.5 0.4 Perception
1.3 4 – 15 Surprise
3 – 22 15 – 88 Let’s Go (Reflex Action)
22 – 40 80 – 160 Muscular Inhibition
40 – 100 160 – 300 Respiratory Block
More than 100 More than 300 Usually Fatal
Electrical Shock Hazards & Effects on Human Body

Why AC is More Dangerous than DC?

Following are some reasons showing that AC is more dangerous than DC.

RMS and Peak Value

The domestic supply in our homes are 230V AC (in EU) and 120V AC in US. It is the effective or RMS Voltage. It means that alternating voltage available has the same heating effect as 230V DC or 120V AC respectively.

The equation of this alternating current is

V = Vm Sin ω t

Where

  • Vm = √2 VRMS
  • ω = 2π … (= 50 0r 60 Hz Frequency)

Putting the values and solving for Voltage:

230 x √2 Sin x 2 (3.1415) x 50Hz x t

230 x √2 Sin x 314 x t Volts.

Now the Peak Value of AC Voltage or Current, (this doesn’t apply on DC due to the alternating sinusoidal waves of AC).

VRMS = VPK ÷ √2     or    VRMS = 0.707 x VPK

Similarly,

IRMS = IPK ÷ √2     or    IRMS = 0.707 x IPK

Using the above formula, we find the value of AC Peak Voltage and Current as follow

VPK = √2 x VRMS     and    IPK = √2 x IRMS

To calculate the max or peak value of AC Voltage for our homes supply (where home supply is 230V or 120V AC)

VPK = 1.414 x 230V = 325V AC (or 170V Peak AC in case of 120V AC home supply).

The above calculation shows that our home supply voltage which is 230V AC or 120V AC are RMS voltages and the Peak voltages of these RMS voltages are 325V or 170V or 650 peak to peak or 320 peak to peak voltages.
Respectively, whereas DC has only RMS value which is contact i.e 230V DC or 120V DC.

In other words, for both AC and DC having the same level of Voltage, AC turns out to be about 325V or 170V i.e. it’s more than it appears and yes, the more voltage, the higher the chance of electrocution. In short, More DC voltage or current is needed to induce the same hazardous effect as AC voltage and current.

Capacitance

A victim body acts as an insulating medium between the live wire and ground leading to capacitance. But we know that a capacitor blocks DC while AC can pass through it. Let’s see mathematically,

  • Frequency in DC = 0Hz
  • Frequency in AC = 50 or 60 Hz.

Resistance in DC:

XC = 1 ÷ 2πfC in Ω

If we put “f = frequency” as zero, then the capacitive reactance (XC) would be infinite. That’s why the capacitor blocks DC to pass through it.

Now resistance in AC (also known as impedance)

Impedance Z = √ (R2 + XC2)

If we put frequency as 50 or 60Hz, the overall impedance (i.e. resistance) would decrease. This way, AC has the ability to easily pass through the capacitor. It means AC is more dangerous than DC in cases when the human body acts as a capacitor.

In short, the impedance and resistance in DC is lower than AC as it decreases when frequency increases. This way, AC is more harmful than DC.

Frequency

Some having the concept that DC is more dangerous than AC with the same level of voltage because AC changes it direction multiple times (i.e. AC touches the zero value 50 or 60 times) per second due to frequency and there is a chance for the victim to skip the shock, whereas there is no frequency in DC.

Now if we consider the frequency as 60 or 50Hz, let’s see how fast AC changes its direction.

T = 1 ÷ f

T = 1 ÷ 50Hz = 0.02 Seconds.

It shows that AC touches the zero point after each 0.20 seconds, where the human brain is not that much faster (except the unintentional functions) to respond to electric shock and move back from the voltage source.

The 50 or 60Hz frequency plays an important role in the electric shock effect on the human body. For example, the low voltage about 25V AC with 60 Hz are harmful (wet and humid body).

Note: Both AC and DC voltages and currents are dangerous. Don’t touch the live wires. In case of electric shock, try to disconnect the power supply and push back the victim’s body from the source (keep in mind that you should be properly insulated before doing so). Only call the professional electrical in case of repairing or troubleshooting. In case of emergency, call the local authority ASAP.

FAQ

Which is more dangerous, AC or DC and why?

One of the reasons that AC might be considered more dangerous is that it arguably has more ways of getting into your body. Since the voltage alternates, it can cause current to enter and exit your body even without a closed loop, since your body (and what ground it’s attached to) has capacitance. DC cannot do that

Why AC is more better than DC?

Following are the advantages of alternating current over direct current: AC is less expensive and easy to generate than DC. AC can be transmitted across long distances without much energy loss, unlike DC. The power loss during transmission in AC is less when compared to DC

Which is more dangerous 220v AC or DC?

The dangers of alternating current (A.C.) are five times greater than the dangers of direct current (DC) (D.C). The main cause of this harmful effect on the human body is the alternating current’s frequency

Which is more dangerous, 230v DC or 230v AC?

Which is more dangerous 230v DC or 230v AC? 230v DC is more dangerous because it does not have zero crossing i.e constantly 230v is coming. In the case of 230v AC, the voltage varies between 230 to 0 -230 so it is less dangerous compared to 230v dc

Why is AC preferred over DC?

AC power can easily be step-up or step down with the help of a transformer which is not possible in the case of DC power. Electricity that is coming to our homes is AC because it comes from a far away power generation plant so the loss of energy during transmission is very less in the case of AC power than DC power

Why is DC current not used in homes?

DC current is not used in homes because of the following reasons: First of all, DC is difficult to generate because primarily it is generated by batteries and electrochemical of photovoltaic cells. Power loss during transmission is more in direct current as compared to alternating current

Is AC or DC safer?

How Dangerous is DC Current? If you compare AC to DC, then studies indicate that AC is around five times more dangerous. The human body is naturally more resistant to DC than AC and it has been proven that letting go – therefore escaping the impact of electrical shock – of live parts in a DC circuit is easier

Is AC or DC more powerful?

Direct current (or DC) isn’t inherently stronger than alternating current (or AC). AC is easier to convert from high voltage power lines to 120V household electricity using a transformer, making it the primary choice for grid infrastructure

Share this post:

Related Tips

Reading Time: 10:5 min

What is the Suitable Wire Size for 20A Breaker and Outlet?

How to Find the the Right Wire Size for a 20-Amp Breaker and Outlet Based on NEC? Choosing the the…

View post

Reading Time: 7:39 min

Why Do We Need to Install a Starter with a Motor?

Why Do We Need to Connect a Starter with Electrical Motors? Essential and Need of Starter with Motor A starter is a device used…

View post

Reading Time: 4:22 min

Why are Generators and Alternators Rated in kVA, Not in kW?

Why is an Alternator or Generator Rated in kVA, Not in kW? As we already know that why is a transformer…

View post

Reading Time: 4:41 min

Why Does AC Need More Insulation than DC at the Same Voltage Level?

Why Does AC Voltage Require More Insulation than DC Voltage for the Same Working Voltage Level? For the same working…

View post

Reading Time: 3:54 min

Why is a Power Plant Capacity Rated in MW and not in MVA?

Why is the Rating of a Power Plant Capacity Expressed in MW instead of MVA? For the following reasons, a…

View post

Reading Time: 6:36 min

Why are Overhead Power Lines Loose on Electric Poles & Towers?

Why are Overhead Power Lines Loose on Utility Poles and Transmission Towers? Transportation of people, goods, and services today is…

View post

Reading Time: 9:31 min

Why Radio Waves Are Chosen For Close Range Transmission?

Why Radio Waves Are Chosen For Close Range Transmission? INTRODUCTION Back then in the stone ages, information were disseminated either…

View post

Reading Time: 6:5 min

Why Don’t Birds and Squirrels Get Electrocuted on Power Lines?

Why Don’t Birds Setting on Power Lines Get Electrocuted? We mentioned many times that electricity is our best friend as…

View post
Subscribe to our

Newsletter

We will update you with all the latest books and references.